Link to the University of Pittsburgh Homepage
Link to the University Library System Homepage Link to the Contact Us Form

Dynamic right and left ventricular interactions in the rabbit: Simultaneous measurement of ventricular pressure-volume loops

Pinsky, MR and Perlini, S and Solda, PL and Pantaleo, P and Calciati, A and Bernardi, L (1996) Dynamic right and left ventricular interactions in the rabbit: Simultaneous measurement of ventricular pressure-volume loops. Journal of Critical Care, 11 (2). 65 - 76. ISSN 0883-9441

[img] Plain Text (licence)
Available under License : See the attached license file.

Download (1kB)

Abstract

Purpose: This study was performed to characterize the dynamic factors determining ventricular interdependence in an open-pericardium intact animal model. Materials and Methods: Simultaneous measures of right ventricular (RV) and left ventricular (LV) pressures and volumes in 6 urethane-anesthetized open-chested, open pericardium rabbits. RV and LV V were calculated every 2 milliseconds. Measurements were made at initial baseline blood volume, and again after two infusions of 20 mL/kg isoconductive colloid solution. At each blood volume level, partial aortic (AO), pulmonary artery (PAO), and inferior vena caval (IVC) occlusions were performed. Biventricular diastolic compliance and end-systolic elastance were calculated from these data. Results: Baseline end-diastolic (ED) and end-systolic (ES)V were 3.29 ± 0.55 and 2.43 ± 0.33 mL (x ± SD) for the LV, and 3.38 ± 1.56 and 2.84 ± 1.36 mL for the RV, respectively. AO increased all LV pressure and volume (P < .05) but did not alter RV ED volume (2.85 ± 1.20 mL) or ED pressure (3.3 ± 2.0 to 3.6 ± 2.1 mm Hg). PAO increased RV ES pressure (P < .05) but did not alter RV ED volume, ED pressure, or ES volume, although it decreased LV ED volume (2.82 ± 0.59, P < .05). AO also immediately increased end systolic RV elastance to a value greater than that defined by IVC (7.9 ± 4.4 to 10.9 ± 6.6 mm Hg/mL,P < .05). Intra-vascular volume expansion though increasing baseline pressure and volume, did not alter qualitatively biventricular responses to AO, PA, or IVC. Conclusion: Ventricular interdependence has both systolic and diastolic components that have differing directional effects. In the pericardectomized rabbit, increases in RV ED volume decrease LV ED volume by decreasing LV diastolic compliance, but do not alter LV systolic function. Whereas, increases in LV ED volume decrease RV ES volume resulting in an increase in RV maximal elastance, but minimally alter RV diastolic function.


Share

Citation/Export:
Social Networking:
Share |

Details

Item Type: Article
Status: Published
Creators/Authors:
CreatorsEmailPitt UsernameORCID
Pinsky, MRpinsky@pitt.eduPINSKY0000-0001-6166-700X
Perlini, S
Solda, PL
Pantaleo, P
Calciati, A
Bernardi, L
Date: 1 January 1996
Date Type: Publication
Journal or Publication Title: Journal of Critical Care
Volume: 11
Number: 2
Page Range: 65 - 76
DOI or Unique Handle: 10.1016/s0883-9441(96)90022-2
Schools and Programs: School of Medicine > Critical Care Medicine
Refereed: Yes
ISSN: 0883-9441
PubMed ID: 8727028
Date Deposited: 05 Mar 2012 19:54
Last Modified: 30 Jan 2020 16:55
URI: http://d-scholarship.pitt.edu/id/eprint/11234

Metrics

Monthly Views for the past 3 years

Plum Analytics

Altmetric.com


Actions (login required)

View Item View Item