Link to the University of Pittsburgh Homepage
Link to the University Library System Homepage Link to the Contact Us Form

Comparison of Speech Intelligibility Measures for An Electronic Amplifying Earmuff and An Identical Passive Attenuation Device

Byrne, David C. and Palmer, Catherine V. (2012) Comparison of Speech Intelligibility Measures for An Electronic Amplifying Earmuff and An Identical Passive Attenuation Device. Audiology Research, 2 (1). pp. 17-24. ISSN 2039-4349

[img]
Preview
PDF
Published Version

Download (332kB) | Preview

Abstract

The purpose of this study was to identify any differences between speech intelligibility measures obtained with MineEars electronic earmuffs (ProEars, Westcliffe, CO, USA) and the Bilsom model 847 (Sperian Hearing Protection, San Diego, CA, USA), which is a conventional passive-attenuation earmuff. These two devices are closely related, since the MineEars device consisted of a Bilsom 847 earmuff with the addition of electronic amplification circuits. Intelligibility scores were obtained by conducting listening tests with 15 normalhearing human subject volunteers wearing the earmuffs. The primary research objective was to determine whether speech understanding differs between the passive earmuffs and the electronic earmuffs (with the volume control set at three different positions) in a background of 90 dB(A) continuous noise. As expected, results showed that speech intelligibility increased with higher speech-to-noise ratios; however, the electronic earmuff with the volume control set at full-on performed worse than when it was set to off or the lowest on setting. This finding suggests that the maximum volume control setting for these electronic earmuffs may not provide any benefits in terms of increased speech intelligibility in the background noise condition that was tested. Other volume control settings would need to be evaluated for their ability to produce higher speech intelligibility scores. Additionally, since an extensive electro-acoustic evaluation of the electronic earmuff was not performed as a part of this study, the exact cause of the reduced intelligibility scores at full volume remains unknown.


Share

Citation/Export:
Social Networking:
Share |

Details

Item Type: Article
Status: Published
Creators/Authors:
CreatorsEmailPitt UsernameORCID
Byrne, David C.
Palmer, Catherine V.cvp@pitt.educvp
Date: 24 February 2012
Date Type: Publication
Journal or Publication Title: Audiology Research
Volume: 2
Number: 1
Publisher: MDPI AG
Page Range: pp. 17-24
DOI or Unique Handle: 10.4081/audiores.2012.e5
Schools and Programs: School of Health and Rehabilitation Sciences > Communication Science and Disorders
Refereed: Yes
Uncontrolled Keywords: noise, hearing protection, speech intelligibility
ISSN: 2039-4349
Official URL: http://dx.doi.org/10.4081/audiores.2012.e5
Article Type: Research Article
Date Deposited: 25 May 2021 19:37
Last Modified: 25 May 2021 19:37
URI: http://d-scholarship.pitt.edu/id/eprint/41144

Metrics

Monthly Views for the past 3 years

Plum Analytics

Altmetric.com


Actions (login required)