Link to the University of Pittsburgh Homepage
Link to the University Library System Homepage Link to the Contact Us Form

Quantification of Chronic Microelectrode Signal Quality over Time

Sleight, Trevor W (2010) Quantification of Chronic Microelectrode Signal Quality over Time. Master's Thesis, University of Pittsburgh. (Unpublished)

[img]
Preview
PDF
Primary Text

Download (1MB) | Preview

Abstract

The developing field of brain machine interface contains enormous potential for therapeutic benefit. One of the most direct interfaces is the penetrating microelectrode array. However, the failure of chronically implanted neural probes limits the usefulness of penetrating microelectrodes for human brain machine interfaces. Over the course of several weeks after implantation, neural probes lose their ability to record signals due to a variety of tissue reactions including neuronal loss and glial scarring. Several forms of surface enhancements and drug delivery solutions have been proposed. However, in order to systematically evaluate these techniques, a reliable chronic recording model is needed that can offer quantification of recording quality, longevity and reliability. The results of this study are twofold. We present several parameters that may be used as metrics for quantifying the decay of signal quality in a microelectrode array. Second, we consider the effects of a potential surface modification for improving these parameters. In this study, we characterized the quality of neural recordings obtained from microelectrode arrays (16-channel, NeuroNexus, Inc, 16-channel, MicroProbes for Life Science) implanted chronically in the barrel cortex of adult rats. Signal to noise ratio of unit waveforms, local field potential and the ability of the implants to respond to a variety of stimulation parameters were evaluated as measures of the survival of the probe. L1 is a neural adhesion molecule that can specifically promote neurite outgrowth and neuronal survival. Previous in-vitro studies have suggested that that a surface modification of L1 may be able to increase the neuronal density local to the probe. We compared the signal degradation of L1 modified probes and control probes over 8 weeks. The data suggests trends towards improved signal to noise ratio in the L1 coated probes.


Share

Citation/Export:
Social Networking:
Share |

Details

Item Type: University of Pittsburgh ETD
Status: Unpublished
Creators/Authors:
CreatorsEmailPitt UsernameORCID
Sleight, Trevor Wtws20@pitt.eduTWS20
ETD Committee:
TitleMemberEmail AddressPitt UsernameORCID
Committee ChairCui, Xinyan Tracyxic11@pitt.eduXIC11
Committee CoChairWeber, Douglasdjw50@pitt.eduDJW50
Committee MemberSimons, Danielcortex@pitt.eduCORTEX
Date: 25 June 2010
Date Type: Completion
Defense Date: 23 March 2010
Approval Date: 25 June 2010
Submission Date: 7 April 2010
Access Restriction: 5 year -- Restrict access to University of Pittsburgh for a period of 5 years.
Institution: University of Pittsburgh
Schools and Programs: Swanson School of Engineering > Bioengineering
Degree: MSBeng - Master of Science in Bioengineering
Thesis Type: Master's Thesis
Refereed: Yes
Uncontrolled Keywords: Chronic Barrel Signal Quality
Other ID: http://etd.library.pitt.edu/ETD/available/etd-04072010-005256/, etd-04072010-005256
Date Deposited: 10 Nov 2011 19:35
Last Modified: 15 Nov 2016 13:38
URI: http://d-scholarship.pitt.edu/id/eprint/6867

Metrics

Monthly Views for the past 3 years

Plum Analytics


Actions (login required)

View Item View Item