Evaluation of Rotational Mechanisms to Enhance Performance of a Respiratory Assist Catheter

Mihelc, Kevin Michael (2007) Evaluation of Rotational Mechanisms to Enhance Performance of a Respiratory Assist Catheter. Master's Thesis, University of Pittsburgh. (Unpublished)

[img]
Preview
PDF
Primary Text

Download (2MB) | Preview

Abstract

A percutaneous respiratory assist catheter is being developed to partially support native lung function in patients with acute respiratory distress syndrome (ARDS) and acute exacerbations of chronic obstructive pulmonary disease (COPD). Current clinical therapies include pharmacotherapy, mechanical ventilation, and ECLS, but are associated with high mortality rates. The catheter is intended for insertion through the femoral vein for placement in the vena cava where it actively processes venous blood. The artificial lung device consists of a hollow fiber membrane (HFM) bundle that supplements oxygenation and carbon dioxide removal through diffusional processes.The catheter is a second generation concept of the Hattler Catheter with a design goal of size reduction to accommodate percutaneous insertion. The tradeoff in available HFM surface area requires the catheter to be more efficient in removing CO2 per unit surface area. Two prototypes utilizing rotational mechanisms to actively mix the blood and reduce mass transfer boundary layers were evaluated. The first prototype consisted of a rotating HFM bundle capable of rates of 10,000 RPM but required a structure for vessel wall protection. The second prototype employed a rotating impeller within a stationary HFM bundle to internalize rotational components within the device. The prototypes were evaluated in vitro and in vivo to assess design and performance. Development of impeller geometries, a saline seal purge, and device flexibility were notable design highlights. Acceptable hemolysis levels were observed in testing the concept of using a high-speed rotational HFM bundle. Standard gas exchange characterization tests in DI water showed over a two-fold increase in CO2 removal efficiency of 450 and 529 ml CO2/min/m2, rotational catheter and impeller catheter respectively, over the Hattler Catheter. The impeller catheter was evaluated in a bovine model and an average efficiency of 513 ± 20 ml CO2/min/m2 was attained at 20,000 RPM. Catheter size reduction and CO2 removal efficiency enhancements were successfully achieved. A separate novel method to augment CO2 concentration gradients is being researched to integrate with HFMs and attain overall gas exchange project goals.


Share

Citation/Export:
Social Networking:
Share |

Details

Item Type: University of Pittsburgh ETD
Status: Unpublished
Creators/Authors:
CreatorsEmailPitt UsernameORCID
Mihelc, Kevin Michaelkmm100@pitt.eduKMM100
ETD Committee:
TitleMemberEmail AddressPitt UsernameORCID
Committee ChairFederspiel, William J.federspielwj@upmc.eduWFEDERSP
Committee MemberHattler, Brack G.hattlerbg@upmc.edu
Committee MemberBorovetz, Harvey S.borovetzhs@msx.upmc.edu
Date: 25 September 2007
Date Type: Completion
Defense Date: 11 May 2007
Approval Date: 25 September 2007
Submission Date: 28 June 2007
Access Restriction: 5 year -- Restrict access to University of Pittsburgh for a period of 5 years.
Institution: University of Pittsburgh
Schools and Programs: Swanson School of Engineering > Bioengineering
Degree: MSBeng - Master of Science in Bioengineering
Thesis Type: Master's Thesis
Refereed: Yes
Uncontrolled Keywords: artificial lung; catheter; CO2 removal; hemolysis; hollow fiber membrane; mechanical ventilation; oxygenator; respiratory assist
Other ID: http://etd.library.pitt.edu/ETD/available/etd-06282007-161652/, etd-06282007-161652
Date Deposited: 10 Nov 2011 19:48
Last Modified: 19 Dec 2016 14:36
URI: http://d-scholarship.pitt.edu/id/eprint/8215

Metrics

Monthly Views for the past 3 years

Plum Analytics


Actions (login required)

View Item View Item