Validation of Heat Flux Technology to Assess Energy Expenditure During Exercise

Thomas, Erin Lynn (2005) Validation of Heat Flux Technology to Assess Energy Expenditure During Exercise. Doctoral Dissertation, University of Pittsburgh. (Unpublished)

[img]
Preview
PDF
Primary Text

Download (1MB) | Preview

Abstract

There are limitations to current portable technology to estimate energy expenditure (EE), which may limit the accuracy when applied to free-living individuals. The KAL-X SensorTM (Lifechek, LLC, Pittsburgh, PA) uses heat flux technology to estimate EE. The accuracy of this device has not been assessed across levels of body mass index (BMI). The purpose of this study was to examine the validity of the KAL-X SensorTM to measure EE across different modes and intensities of physical activity. Twenty-four subjects (age = 33.8 ± 8.5 yr, BMI = 27.55 ± 3.9 kg/m2) performed two exercise (treadmill walking, stationary cycling) sessions with each lasting 30 minutes. Walking included three 10-minute progressive intervals of 2.5 mph, 0%; 3.0 mph, 0%; and 3.0 mph, 5%. Cycling included three 10-minute progressive intervals of 50 rev/min, 0.5 kg; 60 rev/min, 0.5 kg; and 60 rev/min, 1.0 kg. The criterion measure of EE was indirect calorimetry (IC). A KAL-X SensorTM was placed on the upper arm and at the level of the xyphoid process. EE during 30 minutes of walking for the KAL-X SensorTM (arm sensor = 94.5 kcal, chest sensor = 100.9 kcal) was significantly lower than EE measured using IC (166.5 kcal) (p<0.05). EE during 30 minutes of cycling for the KAL-X SensorTM (arm sensor = 76.4kcal, chest sensor = 90.1 kcal) was significantly lower than EE measured using IC (138.0 kcal) (p<0.05). The level of BMI did not affect the pattern of results, nor did arm circumference or skinfold measured at the bicep or tricep. These results indicate that there are limitations of the KAL-X SensorTM to provide an accurate estimate of EE during walking and cycling exercise. Additional research is needed to determine the accuracy of the KAL-X SensorTM to estimate EE during other forms of exercise, lifestyle activity, and free-living activity.


Share

Citation/Export:
Social Networking:
Share |

Details

Item Type: University of Pittsburgh ETD
Status: Unpublished
Creators/Authors:
CreatorsEmailPitt UsernameORCID
Thomas, Erin Lynnelt5@pitt.eduELT5
ETD Committee:
TitleMemberEmail AddressPitt UsernameORCID
Committee ChairJakicic, John Mjjakicic@pitt.eduJJAKICIC
Committee MemberOtto, Amy Dayotto@pitt.eduAYOTTO
Committee MemberGoodpaster, Bret Hbgood@pitt.eduBGOOD
Committee MemberRobertson, Robert Jrrobert@pitt.eduRROBERT
Date: 6 December 2005
Date Type: Completion
Defense Date: 21 November 2005
Approval Date: 6 December 2005
Submission Date: 5 December 2005
Access Restriction: No restriction; Release the ETD for access worldwide immediately.
Institution: University of Pittsburgh
Schools and Programs: School of Education > Health, Physical, Recreational Education
Degree: PhD - Doctor of Philosophy
Thesis Type: Doctoral Dissertation
Refereed: Yes
Uncontrolled Keywords: Energy Expenditure; Heat Flux; Portable Device